Q-switched laser is a laser in which a shutter, the Q-switch, releases stored energy as a single pulse of about a billionth of a second, a nanosecond, commonly at 532 and 1064 nm. Q-switched lasers fragment pigment and tattoo ink so the body can clear them, but with more photothermal, heat-based contribution than a picosecond laser, whose pulses are roughly a thousand times shorter. It is the older generation; neither is a brand or a treatment plan.

A Q-switched laser is defined by its nanosecond pulse, not its wavelength: Q-switched Nd:YAG at 1064 and 532 nm, Q-switched alexandrite at 755 nm and Q-switched ruby at 694 nm all exist, with melanin and tattoo ink as the chromophores. On this site the term appears wherever the older and newer pigment lasers are compared.
Q-switched is not obsolete and pico is not magic; the pulse I choose depends on the mark in front of me and the skin around it.— Dr Sin Yong
The pigmentation worse after laser post explains the heat-spread mechanism that makes nanosecond pulses riskier in darker skin.
Q-switched is a pulse mechanism, so it is confused with the wavelengths it is built in and the class that replaced it.
Neither Q-switched nor picosecond is a treatment plan; both are tools chosen per mark, per visit.
The older pulse form still has jobs, and the choice between it and picosecond is made on the mark, the skin and the history.
Dr Sin Yong treats the Q-switched emission as one setting among several, used where a nanosecond pulse is the right physics for the mark.
The difference between Q-switched and picosecond lasers is pulse width, and pulse width changes the mechanism: a pulse shorter than the time a pigment particle takes to pass heat to its surroundings shatters it by a pressure wave with little heat spreading outward, while a nanosecond pulse heats the particle and some of the skin around it. The comparison is set out on pico vs Q-switched laser. In Dr Sin Yong's practice the DEKA TORO used for T2 Frax Radiance carries 532 and 1064 nm nanosecond emissions alongside its 785 nm picosecond emission, so the choice is made per mark and per visit. Q-switched toning keeps a role in low-fluence 1064 nm work for diffuse tone, with a stopping point; the newer class is defined under picosecond laser and the main platform on pico laser.
It is a difference in delivery, not a verdict. Nanosecond pulses leave more heat in the skin, which matters for post-inflammatory hyperpigmentation in Fitzpatrick III to V skin, but fluence, spot size, wavelength and interval still decide the outcome on either pulse width.
In low-fluence 1064 nm toning for diffuse tone and brown marks after acne, yes, and not on an open-ended schedule. Discrete sun spots and freckles are usually treated with the picosecond emission instead.
Torbeck RL, Schilling L, Khorasani H, Dover JS, Arndt KA, Saedi N. Evolution of the picosecond laser: a review of literature. Dermatol Surg. 2019;45(2):183-194. doi:10.1097/DSS.0000000000001697. source
Postinflammatory Hyperpigmentation Associated with Treatment of Solar Lentigines Using a Q-Switched 532-nm Nd:YAG Laser: A Multicenter Survey. PubMed, 2016. pubmed.ncbi.nlm.nih.gov
Review of Laser Treatments for Post-Inflammatory Hyperpigmentation in Skin of Color. PubMed, 2023. pubmed.ncbi.nlm.nih.gov
Treatment of Solar Lentigines: A Systematic Review of Clinical Trials. Journal of Cosmetic Dermatology (PMC), 2025. pmc.ncbi.nlm.nih.gov
Consultations by appointment at Orchard Road, Singapore.
Replies within clinic hours: Mon–Fri 10am–8pm, Sat 11am–3pm · How consultations work · Prefer not to use WhatsApp? · Treatment finder
WhatsApp +65 8023 7170 →